  4. Liquid analyzers: sum parameters (DOC, BOD, COD...)
  5. water analyzer / concentration / benchtop / waterproof
Water Analyzer / Concentration / Benchtop / Waterproof

water analyzer / concentration / benchtop / waterproof

AL200 COD

INO Group

water analyzer / concentration / benchtop / waterproof
Request for quotation
captcha contact product
  • Characteristics
  • Detail
  • Comment/Review
  • Measured entity:

    water

  • Measured value:

    concentration

  • Configuration:

    benchtop

  • Other characteristics:

    waterproof, photometric

Highlights

ST-COD sealed tubes ready for use
Suppression of chloride interference
up to 1000 mg/l (LR & MR)
up to 10000 mg/l (HR)
3 ranges:
Low range: 0 – 150 mg/l
Middle range: 0 – 1500 mg/l
High range: 0 – 15000 mg/l

Description
Waste water parameter COD

The chemical oxygen demand, ST-COD value (ST = small scale sealed tube), of water as determined by this dichromate method can be considered as an estimate of the theoretical oxygen demand, i.e. the amount of oxygen con- sumed in total chemical oxidation of the organic constituents present in the water.

AL200 COD VARIO Photometer

With a measuring range from 0 to 15,000 mg/l O2, the AQUALYTIC® COD VARIO photometer are suitable for waste water testing.

Two LEDs light sources with long-term stability (λ1 = 430 nm ; λ2 = 610 nm, according to ISO 15705:2002), a waterproof sample chamber, a large digital display, and the user-friendly keypad ensure maximum operating reliability and convenience.
Setup AL200 COD

The AQUALYTIC® COD VARIO set-up allows highly sensitive and precise water testing with minimum effort. It measures the ST-COD concentration by photometric detection employing a linear relationship between absorbance and concentration.

After adding the sample to a AQUALYTIC® COD VARIO tube test (LR, MR according to ISO 15705:2002), it is heated in the reactor and then analysed in the photometer.

Set-Up AL200 COD VARIO

The AQUALYTIC® COD VARIO set-up allows highly sensitive and precise water testing with minimum effort. It measures the ST-COD concentration by photometric detection employing a linear relationship between absorbance and concentration.

View catalogue Go to the AQUALYTIC website for more information