analog expansion module for movement controllers / 16-bit
QAIO series
INO Group
-
Options:
analog for movement controllers
-
Other characteristics:
16-bit
Analog module features 16 bit resolution of the inputs and outputs. All inputs and outputs are updated at every program cycle of the MSC I or MSC II. The minimum cycle time is 100 µs at MSC II and 400 µs at MSC I.
2 analog inputs, each configurable in the MACS development environment as ±10 V, ±10 mA or 4-20 mA
2 analog outputs, each ±10 V and additionally configurable as ±10 mA, ±50 mA or 4-20 mA, with wire fault detection
1 reference voltage output: +10 V, short circuit protected
The module is mounted on a DIN top-hat rail and connected to an MSC I or MSC II via the internal extension bus (E-bus).