Technology:
vortex
-
Fluid:
for liquids
-
Mounting:
insertion
-
Other characteristics:
precision
-
Protection level:
IP67
-
Process pressure:
10 bar (145.04 psi)
-
Process temperature:
Min.: 0 °C (32 °F)
Max.: 60 °C (140 °F)
-
Volumetric flow rate:
Min.: 0.9 l/min (0.24 us gal/min)
Max.: 150 l/min (39.63 us gal/min)
Flow measurement device using the vortex measurement principle
●High precision
●High stability to excessive flow rates
●No moving parts
●Rapid installation and removal thanks to clamp fastening
●Various connections using building block system
Characteristics
A narrow triangular body (1), which goes through the complete
cross-section of the measurement pipe, creates vortices in the
medium when there is a flow (Kármán vortex street, vortex effect).
The frequency of the vortex is proportional to the flow, and is
detected using a piezo-sensor (2), which lies behind the triangular
body. The complete unit, vortex body, and detector are designed as
a plug-in unit (3), and are inserted into the pipe. Here, a lightning
fast separation between measurement pipe and the complete
measurement unit is possible.