Technology:
inductive, Coriolis, mass
-
Fluid:
for gas
-
Mounting:
in-line
-
Other characteristics:
compact
-
Domain:
sanitary
-
Process pressure:
Min.: 0 bar (0 psi)
Max.: 100 bar (1450.38 psi)
-
Process temperature:
Min.: -50 °C (-58 °F)
Max.: 180 °C (356 °F)
-
Mass flow rate:
Min.: 2130 kg/h (4695.85 lb/h)
Max.: 510000 kg/h (1124358.45 lb/h)
The SITRANS F C MC2 DN 50 to 150 is appropriate for precise mass flow dimension for all types of gases and fluids owing to the high precision, which is better than 0.15 percent of the mass stream rate. Owing to the adaptability, the meter is simple to set up and is known for its high precision in an extensive turndown variety which is a vital in several applications. The detector is planned with a corresponding S-tube and best oriented inductive hoists increasing the precision and turn-down array in addition to a space economy dense split-flow detector design enabling low pressure drop. The SITRANS F C MC2 is self-exhausting in both vertical and horizontal position. The SITRANS F C MC2 as well comprises an EHEDG permitted clean version derived from the SITRANS F C MC2 normal design. The clean version is available in the dimensions DN 20 to DN 80 covering the necessary dimensions...