superheated steam sterilizer / process / high-pressure / rotary
SUPERHEATED STEAM STERILIZER FOR POWDER AND GRANULES
INO Group
-
Laboratory/process:
process
-
Sterilization method:
superheated steam
-
Other characteristics:
high-pressure, rotary
-
Applications:
for pharmaceutical industry, for the food industry
Superheated Steam Continuous Sterilizing System Exclusive for Granules "SIRV"
This system is dedicated exclusively to granules. It has a compact and easy-maintenance design, thanks to its special high-pressure rotary valve.
The inlet material is distributed in a small amount to be sterilized as if it were treated with a "continuous rotary autoclave." This model incorporates a vibrating dryer cooler suited to dry and cool the granules.
■ Minimal System Configuration
The key component in this system is the specially-designed rotary
valve resulting in an equipment with compact design and easy maintenance.
■ Excellent Sterilization Effect
Superheated steam having big thermal energy is directly blown into
the pockets of the rotary valve instantly killing E coli, viable cells and
thermoduric cells.
■ Minimal Product Deterioration
Short heating time, anaerobic atmosphere and constant temperature in
the pockets of the rotary valve minimizes the product deterioration such as
loss of active ingredients or oxidation.
■ Flexible and User-friendly Operation
The pressure, temperature and heating time are variable to make the
system flexible for granules, seeds, pellets, etc.
■ Easy Cleaning
The pneumatic pipe can be cleaned easily by flushing water from the
product hopper and dried with the inline heater.