Technology:
differential-pressure, orifice
-
Fluid:
for liquids, for gas, for steam
-
Mounting:
vertical-mount
-
Material:
stainless steel, PVC, PP
-
Other characteristics:
4-20 mA
-
Process pressure:
Min.: 0 bar (0 psi)
Max.: 15 bar (217.56 psi)
-
Process temperature:
Min.: -50 °C (-58 °F)
Max.: 300 °C (572 °F)
-
Volumetric flow rate:
Min.: 2 m³/h (70.63 ft³/h)
Max.: 20000 m³/h (706293.32 ft³/h)
Orifice plate flowmeters for liquid, gas and steam service.
Mounting in horizontal or vertical pipes.
Supply of orifice plate and by-pass flowmeter. Isolation valves and by-pass circuit are not supplied.
Application areas
Suitable for fire protection systems and cooling circuits, among others.
Technical specifications
Indication by means of by-pass flowmeter
Materials:
EN 1.4404 (SS 316L), PVC, PP, … others on request
Measuring ranges:
2 m3/h … 20000 m3/h H2O
30 Nm3/h … 300000 Nm3/h air
Accuracy:
+-4% f.s.
Connections:
DN50 … DN1000
Orifice plate mounted between flanges
Flowmeter fittings threaded, flanged or solvent weld socket
Pressure inlets ¾” BSP