INO Group
Hotline:
0947200184
Home
About
Cooperate
Products
News
Contacts
Home
Metrology - Laboratory
Analytical Instrumentation
Electrodes for liquid analysis
Electrodes for liquid analysis
Analytical Instrumentation
Photometers
Colorimeters
Spectrophotometers
Optical spectrometers, fiber optic spectrometers
FT-IR-spectrometers, Raman spectrometers
Spectrofluorometer, filter fluorometers
Atomic emission spectrometers: S-OES, GD-OES, ICP-OES...
Atomic absorption spectrometers, atomic fluorescence spectrometers
X-ray fluorescence spectrometers, XRF analysers
X-ray diffractometers: XRD, SAXS, WAXS
Gamma spectrometers, scintillation counters
Other spectrometers: NMR...
Electron spectrometers: AES, XPS, EELS...
Mass spectrometers
Chromatographs
Chromatography accessories
Particle size analyzers
Samplers
Elemental analyzers
Other material characterization instruments
Other laboratory analyzers
Thermal analyzers: Calorimeters
Thermal analyzers: DSC, TGA, TMA, thermal conductivity analyzers
Liquid analyzers: sum parameters (DOC, BOD, COD...)
Liquid analyzers: metals
Liquid analyzers: disinfection (chlorine, ozone...)
Liquid analyzers: nutrients (NO3, PO4, NH4...)
Liquid analyzers: hardness, salinity
Liquid analyzers: multi-parameter
Fuel and oil analyzers
Other liquid analyzers
Liquid analysis test kits
Probes, transmitters and controllers for liquid analysis
Electrodes for liquid analysis
Sensors for liquid analysis
Conductivity meters
pH meters
Turbidimeters
Refractometers
Polarimeters
Titrators
Gas sensors
Gas transmitters
Gas detection control units
Fixed gas detectors
Fixed gas detectors
Portable gas detectors
Oxygen analyzers (O2)
Hydrogen analyzers (H2)
Analyzers / carbon dioxide
Analyzers / carbon monoxyde
Nitrogen oxides analyzers (NOx)
Total hydrocarbon analyzers (THC)
Sulfur oxides and sulfur compounds analyzers (SOx)
Multi-gas analyzers
Combustion gas analyzers
Other gas analyzers
Air quality monitoring devices
Particle counters
Gas sampling probes
Calibrators for gas detectors and analyzers
Gas analysis equipment
Carbon dioxide analyzers (CO2)
Carbon monoxide analyzers (CO)
pH electrode / glass / process
Orbisint CPS11D
Orbisint CPS11D is the digital all-rounder for process and environmental technology. It measures reliably even in highly alkaline media or hazardous areas. Designed for low maintenance and a long operating life, the electrode offers you ...
pH electrode / glass / laboratory
iPt Titrode
The iPt Titrode by Metrohm is manufactured for use in redox titrations without affecting the pH value. There is an added memory chip for storing sensor data such as calibration data, calibration history, article number and serial number ...
pH electrode / glass / rechargeable / liquid electrolyte
InPro2000 / 2000i
The InPro2000 is a combination pH electrode complete with an inbuilt temperature sensor and is made for exacting applications. The InPro2000 can be ordered with three liquid electrolytes, which increases its range of use. 3M KCl is the ...
pH electrode / ceramic / rechargeable / liquid electrolyte
0 - 14 pH | HA465-50-SC-T-S7
The METLER TOLEDO HA465-50-SC-T-S7 pH Electrode has a reusable electrolyte chemical electrode with patented silver-ion trap. The reusable liquid electrolyte pH electrode is used for durable accurate evaluations in chemical applications. ...
ORP electrode / ceramic / liquid electrolyte
mV | Pt4865-50-SC-P-S7/9848
The Pt4865 is the redox version of 465-50. It is a refillable liquid-electrolyte electrode that is suitable for in-line measurements of oxidation reduction potential (ORP) in biotech applications. It consists of 2 ceramic diaphragms redox ...
ORP electrode / pH / titanium / laboratory
385, 385+ series
The 385/385+ pH/ORP Insertion and Retractable Sensors each feature chemically course Tefzel® product bodies complete with titanium tubes to provide overall optimal resistance. This device is also fully-sealed for maximum sensor leakage ...
ORP electrode / pH / glass / laboratory
3300HT PERpH-X™
Emerson 3300HT and 3300HTVP PERpH-X™ high performance pH and ORP sensors feature a HT design. This design delivers a longer sensor life when employed in high temperatures, coating, fouling, and poisoning applications. The devices are ...
ORP electrode / pH / glass / process
396P/396VP
The ABB AP121 are ORP sensor systems with high accuracy measuring elements of calibration and operation as well as a quick temperature response for a tighter process control. Its compact, slim, IP and NEMA 6P ingress protected design, ...
ion-selective electrode / glass / laboratory
396P/396VP
As sodium is one of the most important parameters which needs to be measured on a boiler plant, ion-selective electrodes (ISEs) are exceptionally useful tools. Operating in the same manner as pH electrodes, sodium ISEs are used to measure ...
ORP electrode / water / rugged
ULTRAPEN™ PT3
This instrument is designed to be extremely accurate, fast, and simple to use in diverse water quality applications. Advanced features include highly stable microprocessor-based circuitry; automatic temperature compensation from 15ºC ...
pH electrode / laboratory
Polilyte Lab series
Polilyte Lab electrodes offer the advantage of being maintenance free with the accuracy and stability required by laboratory electrodes. Thanks to the Single Pore, clogging of the diaphragm is virtually impossible. Maintenance-free, ...
pH electrode / plastic / laboratory
Filltrode
The FillTrode is a robust pH electrode with a plastic shaft and a flat membrane. Use this electrode for your toughest applications! Robust pH electrode with plastic shaft Multiple applications, thanks to its flat membrane: (e.g. for ...
pH electrode / glass / combination / laboratory
Flushtrode
The FlushTrode is ideally suited for viscous, ion-weak, and proteinaceous media. The sleeve diaphragm allows for measurements to be made in tough applications where other pH electrodes cannot. Easy-to-clean, combination glass electrode ...
pH electrode / glass / gel electrolyte / sterilizable
SE 555
Steam-sterilizable sensor providing high reliability and precision The special pH glass enables a very fast and stable response and makes the sensor CIP- and SIP-capable, even in the harshest of environments. The gel electrolyte of ...
pH electrode / ceramic / liquid electrolyte
SE 557
For special requirements and high-precision measurements, with refillable liquid electrolyte. Elimination of typical junction problems resulting in high measurement accuracy in ultrapure water as well as in heavily polluted media and ...